tag: m0154
title: Position Auto-Report
brief: Periodically auto-report position to serial
author: thinkyhead

since: 2.0.8.1
requires: AUTO_REPORT_POSITION
group: hosts

codes: [ M154 ]
related: M114

notes:
  - Requires `AUTO_REPORT_POSITION`.
  - Also enable `EXTENDED_CAPABILITIES_REPORT` to notify hosts about this capability.

parameters:
  -
    tag: S
    optional: true
    description: Interval in seconds between auto-reports. `S0` to disable.
    values:
      -
        tag: seconds
        type: int

examples:
  -
    pre: Report current position every 4 seconds
    code: M154 S4
  -
    pre: Stop reporting position
    code: M154 S0

---

Some host software and serial controllers use `M114` to get the current position, but polling with [`M114`](/docs/gcode/M114.html) is less than optimal, and in older versions of Marlin it would cause print stuttering. With `M154` hosts can simply set an interval and Marlin will keep sending reports automatically. This method is preferred over polling with [`M114`](/docs/gcode/M114.html).